Using the Frame Control Panel > Using the Frame — Controller Settings > Setting Control Parameters > SNMP Traps
SNMP Traps
This screen defines the traps that will be sent by this device.
If you are using SNMPv3, the following settings are available:
SNMPv3 Secure User Name
|
Provide an unique ID for the device.
This string parameter can contain up to 32 characters, and cannot contain a quote (") or back slash (\)
|
SNMPv3 Trap User Security Level
|
This setting determines the level of security applied to sent messages. Authentication signs the message being sent. Privacy encrypts the data portion of the message.
Options are:
- No Authentication and No Privacy
- Authentication Only
- Authentication and Privacy
|
SNMPv3 Trap User Auth Type
|
This option is only available if the security level requires authentication. Options are:
|
SNMPv3 Trap User Auth Key
|
This option is only available if the security level requires authentication.
This string parameter can contain up to 64 characters, and cannot contain a quote (") or back slash (\)string)
|
SNMPv3 Trap User Privacy Type
|
This option is only available if the security level requires privacy. Options are:
|
SNMPv3 Trap User Use Auth Key as Privacy Key
|
This option is only available if the security level requires privacy. Options are Yes and No.
|
SNMPv3 Trap User Privacy Key
|
This option is only available if the privacy key is not the same as the Authentication key.
This string parameter can contain up to 64 characters, and cannot contain a quote (") or back slash (\)
|
- Whether you are using SNMPv2 or SNMPv3, you can define ten trap destinations, as follows:
- SNMP Dest Desc—Description of the host to which SNMP trap messages will be sent.
- SNMP IP Address—If non-zero, specifies the IP address of a host to which SNMP trap messages will be sent.
- Trap/Inform—Choose one or the other. A trap is an event notification; an inform is a trap that retries up to 5 additional times, unless it has been acknowledged.
For SNMPv3 only, configure the Inform Engine Id parameter with the client's engine ID.
|