Using the Frame Control Panel > Using the Frame — Controller Settings > Setting Control Parameters > GPI
GPI
A SEL-MCP3 frame has two GPI inputs and two GPI outputs.
For each GPI input, you can define:
- Function—Specifies the action for the specified GPI input, with options None (default), Alarm Close, Alarm Open, and Load Preset
- Preset—Specifies the system preset to load on the transition from "open" to "close" when the GPI input function is set to Load Preset for the specified GPI input, with the string representing the name of the system preset
The Status field indicates the GPI input contact condition.
For each GPI output, you can define the triggering Function, with options listed below.
- Closed
- Open (default)
- Backup (1-14; primary; secondary)—triggers when a device that is assigned to redundancy takes over for another device, or when it gives up control of that other device
- Minor Alarm
- Major Alarm
The Status field indicates the GPI output contact condition.
The Fault field indicates the GPI output fault state.
|