Using the Frame Control Panel > Using the Frame — Controller Settings > Configuring the Protection Router > Connecting to a Router > Modifying a Legacy Protection Router
Modifying a Legacy Protection Router
Each row in the Protection Router table represents a router level. To modify a row in the Protection Router table, follow these steps:
- Click the row (level) you want to modify.
The parameter list to the right of the Protection Router table updates to display data for that router level. Each parameter in the table below is available for each level in the router.
- Beside Num Inputs, select the number of inputs for this level of the router.
- Beside Num Outputs, select the number of outputs for this level of the router.
The other parameters are optional.
- Select Enable.
Protection Router Parameters
|
|
|
|
Parameter
|
Description
|
Options
|
Enable
|
Enables/disables this router level
|
|
Custom Name
|
Specifies the text name for this router level
|
<String>
|
Num Inputs
|
Specifies the number of input ports that the Selenio output will go to for this router level
|
0 to 32
|
Num Outputs
|
Specifies the number of output ports that are connected to the input of the Selenio frame for this router level
|
0 to 32
|
Subtype
|
Specifies the expected data type for ports on this router level
|
|
|
Output
|
Displays a router table for the selected router level; see Using the Router Output Table
|
Show Table
|
When you have finished configuring the Router Protection settings, the selected levels, and the selected inputs and outputs on those levels, the new data will appear on the Connections panel as protection router interface options.
|